Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Exp Ophthalmol ; 37(1): 68-80, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19138311

RESUMO

Glaucoma is a leading cause of irreversible blindness worldwide. Retinal ganglion cells and their axons represent the selective target of the disease. When visual function is still intact on standard automated perimetry and optic disc appearance is suspicious, an early diagnosis may be supported by the identification of a retinal nerve fibre layer (RNFL) defect in the peripapillary area. At present days, computer-based, real-time imaging of the peripapillary RNFL is available through instruments of easy use and with high levels of accuracy and reproducibility. Scanning laser polarimetry is performed by a confocal scanning laser ophthalmoscope with an integrated polarimeter (GDx-VCC). There is a considerable amount of scientific evidence about the role of this imaging technique for glaucoma diagnosis. The aim of this review is to describe the principles of operation, the examination procedure, the clinical role, the results of main diagnostic studies and the future development of the software for the scanning laser polarimetry.


Assuntos
Glaucoma/diagnóstico , Microscopia Confocal/métodos , Microscopia Confocal/tendências , Oftalmoscopia/métodos , Oftalmoscopia/tendências , Diagnóstico por Computador , Humanos
2.
Ophthalmologica ; 220(4): 266-71, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16785759

RESUMO

BACKGROUND: To assess intersession reproducibility of retinal nerve fiber layer (RNFL) thickness measurements on scanning laser polarimetry with variable corneal compensation (GDx-VCC) in a sample of healthy subjects and glaucoma patients. METHODS: One eye each from 29 healthy and 29 glaucomatous subjects was selected and underwent RNFL scanning by the same operator at baseline and 1 week later. Glaucoma diagnosis relied on the presence of a reproducible defect on automated perimetry. GDx-VCC parameters considered were those available on page 1 of the printout [TSNIT average and standard deviation (SD), superior and inferior average (SA, IA), Nerve Fiber Indicator]. Reproducibility was assessed by calculating coefficient of variation and intraclass correlation coefficient separately for the two groups and for each parameter. The percentage of eyes with an intersession difference in thickness parameters of more than 5% was also calculated. RESULTS: Coefficient of variation was <6% for TSNIT average, SA and IA in both groups. Corresponding values for TSNIT SD in healthy subjects and in glaucoma patients were 13.7 and 11.4%, respectively, whereas for Nerve Fiber Indicator they were 82.9 and 13.3%. Intraclass correlation coefficient ranged from 0.794 to 0.907 in healthy subjects and from 0.924 to 0.972 in glaucoma patients. In healthy subjects, TSNIT average, SA and IA intersession difference was 5% or less in 55-69% of eyes, whereas the value for TSNIT SD was 34.5%. Corresponding values in glaucomatous eyes ranged from 69 to 79.3% for TSNIT average, SA and IA and was 37.9% for TSNIT SD. CONCLUSIONS: Intersession reproducibility of RNFL thickness measurements on GDx-VCC is high, both in healthy and in glaucomatous eyes. In a few cases, however, intersession variation may be larger than 10%. Caution is necessary while interpreting these changes during follow-up, in order to separate physiological variability from real RNFL thickness variations.


Assuntos
Técnicas de Diagnóstico Oftalmológico/instrumentação , Glaucoma/diagnóstico , Fibras Nervosas/patologia , Células Ganglionares da Retina/patologia , Idoso , Humanos , Lasers , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
3.
Acta Ophthalmol Scand ; 84(3): 375-9, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16704701

RESUMO

PURPOSE: To evaluate whether a significant age-related thinning of the retinal nerve fibre layer (RNFL) is measurable by means of scanning laser polarimetry with variable corneal compensation (GDx-VCC) in a sample of healthy eyes. METHODS: A sample of 324 eyes of 324 healthy subjects (mean age 56 +/- 14 years, range 21-85 years) underwent a complete ophthalmic evaluation, standard automated perimetry and RNFL scan with the GDx-VCC. Temporal-superior-nasal-inferior-temporal (TSNIT), superior and inferior average (SA and IA) values provided on the printout were collected and their mean value averaged from all eyes and also after separating the eyes by gender and by age decades. The values of the three parameters were plotted against age and linear regression was calculated. RESULTS: Ageing is associated with a significant RNFL thinning (0.08 micro, 0.16 micro and 0.12 micro per year for TSNIT, SA and IA, respectively; p < 0.001). Analysis showed a similar association with age decade (p < 0.001 on anova). For the TSNIT average, a 9.5% thinning from baseline values was estimated for a 65-year lifespan. Corresponding values for SA and IA were 16.2% and 11.7%, respectively. CONCLUSIONS: Analysis by GDx-VCC confirmed previous reports about significant age-related RNFL thinning. However, a lower rate per year was found, probably because GDx-VCC measurements are much more reliable than those obtained with the previous generation of polarimeters.


Assuntos
Envelhecimento/fisiologia , Córnea/fisiologia , Técnicas de Diagnóstico Oftalmológico , Fibras Nervosas , Nervo Óptico/citologia , Células Ganglionares da Retina/citologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Birrefringência , Estudos Transversais , Feminino , Humanos , Lasers , Masculino , Pessoa de Meia-Idade , Testes de Campo Visual
4.
Graefes Arch Clin Exp Ophthalmol ; 243(8): 774-9, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-15756574

RESUMO

BACKGROUND: The aim of this study was to evaluate the ability of scanning laser polarimetry (SLP) parameters provided by commercially available GDx with variable corneal compensator (VCC) to discriminate between healthy and glaucomatous eyes. METHODS: Sixty-five healthy and 59 glaucomatous age-matched patients underwent a complete ophthalmological evaluation, an achromatic automated perimetry (AAP), and SLP with GDx-VCC. One randomly selected eye from each subject was considered. All glaucomatous eyes had reproducible visual field defects. Mean values (+/- SD) of all SLP-VCC parameters measured in the two groups were compared. Area under receiver operating characteristics (AUROC) curve and sensitivities at predetermined specificities of >or=80% and >or=95% for each single parameter were calculated. Moreover, the nerve fiber indicator (NFI) diagnostic accuracy was evaluated calculating positive, negative, and interval likelihood ratios (LRs) at different cutoff values. RESULTS: All SLP parameters were significantly different between the two groups (p<0.001). The NFI showed the best AUROC curve (0.938, SE 0.02) whereas temporal, superior, nasal, inferior, temporal (TSNIT) average was second best (0.897, SE 0.03), and normalized superior area was third (0.879, SE 0.04). At fixed specificity >or=95%, sensitivities ranged from 22% to 79.7% whereas for values >or=80%, sensitivities were in the 44.1-89.8% range. At a cutoff NFI value of 30, positive LR was 17.6 (95% CI: 5.8-53.6) and negative LR was 0.19 (95% CI: 0.11-0.33). Interval LRs for NFI showed that values 40 were associated with large effects on posttest probability. CONCLUSIONS: SLP-VCC allows good discrimination between healthy and glaucomatous eyes. New software-provided parameters NFI, TSNIT average, and normalized superior and inferior areas appear to be reliable in the evaluation of glaucomatous disease. In particular, after evaluation on interval LRs, the NFI showed a high diagnostic accuracy for values 40.


Assuntos
Córnea/fisiologia , Técnicas de Diagnóstico Oftalmológico , Glaucoma/diagnóstico , Doenças do Nervo Óptico/diagnóstico , Idoso , Área Sob a Curva , Birrefringência , Reações Falso-Negativas , Humanos , Pressão Intraocular , Lasers , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Curva ROC , Sensibilidade e Especificidade , Transtornos da Visão/diagnóstico , Testes de Campo Visual , Campos Visuais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...